Table 1 Mean (SD) for peak force measurements as well as p-values and cohens’ d effect sizes for comparison of sessions

From: Reproducibility of peak force for isometric and isokinetic multi-joint leg extension exercise

 

Session 2

(N)

Session 3

(N)

pvalue

Effect size

T Iso100

L Iso100

2920.5 (633.0)

1480.4 (300.9)

2959.5 (641.9)

1506.4 (283.6)

0.127

0.100

0.06

0.09

R Iso100 *

1511.5 (333.0)

1555.8 (330.6)

< 0.001

0.13

T Iso140

L Iso140

R Iso140

T 30 mm/s

L 30 mm/s

R 30 mm/s

5461.4 (1130.5)

3219.0 (609.0)

3250.7 (637.7)

4630.4 (893.8)

2585.2 (472.9)

2648.4 (414.7)

5393.1 (1157.1)

3271.0 (613.7)

3278.4 (630.4)

4772.1 (1085.8)

2615.0 (479.7)

2650.5 (513.8)

0.269

0.234

0.464

0.194

0.569

0.960

0.06

0.09

0.04

0.14

0.06

< 0.01

T 600 mm/s

L 600 mm/s

R 600 mm/s

2461.4 (722.4)

1425.5 (332.1)

1446.6 (360.4)

2438.2 (738.4)

1452.8 (316.0)

1445.9 (368.7)

0.539

0.178

0.974

0.03

0.08

< 0.01

  1. N– Newton, T– two-legged, R– right leg only, L– left leg only, Iso100– isometric 100° knee angle, Iso140– isometric 140° knee angle
  2. * significant difference between session 2 and session 3 at p < 0.001